When choosing windows, you may encounter technical terms and abbreviations that are not commonly known. We have prepared a brief explanation of the most frequently used terms to help you navigate your selection process more easily.
Thermal Insulation Parameters
Uw – thermal transmittance of the entire window Indicates how much heat escapes through the entire window, including the frame and glazing. The lower the value, the better the window insulates and the lower the heat losses.
Uf – thermal transmittance of the frame Expresses the thermal insulation of the window frame itself, without the glazing. A lower value indicates better insulation properties of the profile.
Ug – thermal transmittance of the glazing Indicates the thermal insulation of the insulating glass. Modern triple glazing achieves very low values, significantly contributing to energy savings.
Ψg (Psi) – linear thermal transmittance Expresses heat losses at the junction between the glass and the frame. A high-quality warm spacer frame helps to reduce this value and minimize the risk of condensation.
Certifications
PHI Darmstadt (Passive House Institute) An internationally recognized certification awarded by the Passive House Institute in Darmstadt, Germany. It confirms that the product meets the strict requirements for use in passive houses.
Types of Glazing
Double glazing Insulating glass consisting of two panes of glass separated by an inter-pane space.
Triple glazing Modern insulating glass consisting of three panes of glass and two insulating cavities. It provides significantly better thermal and acoustic insulation.
VSG (Laminated Safety Glass) Two or more panes of glass joined by a safety film. If broken, shards remain attached to the film, increasing safety.
ESG (Toughened Safety Glass) Thermally toughened glass with higher mechanical resistance. When broken, it shatters into small, blunt fragments, reducing the risk of injury.
Window Types
FIX A fixed glazed window with no opening function. It features a larger glazed area and better thermal insulation parameters.
Tilt-and-Turn Window The most common type of window, allowing for classic opening and ventilation by tilting the sash.
Sliding Systems
HS Portal (Lift-and-Slide Doors) A large-format sliding system designed for wide glazing and barrier-free connection between the interior and a terrace or garden.
PSK Portal A tilt-and-slide system where the sash first tilts and then slides to the side. Particularly suitable for smaller dimensions.
Materials
Euro-beam A multi-layered glued wooden profile made from several layers of wood. Compared to solid wood, it offers higher stability and a lower risk of deformation.
Wood-Aluminum A combination of a wooden profile on the interior side and a protective aluminum cladding on the exterior. It combines the natural look of wood with minimal maintenance requirements.
Surface finish
RAL An international system of color shades used to designate the colors of aluminum profiles and other building elements.
Acoustics
Rw – Airborne Sound Insulation Indicates the window's ability to dampen noise from the exterior. A higher value means better acoustic comfort indoors.
Solar Parameters
g-value Expresses how much solar energy passes through the glazing into the interior. It affects room overheating and passive solar gains.
Confused about technical parameters? You don't need to know all the abbreviations or standards. We will gladly explain the differences between individual solutions and recommend the windows that best suit your project. Contact us →
Request a Price Quote
Are you interested in a non-binding price quote? Please complete the form and we will contact you. Ensure that your contact information is entered correctly. Fields marked with * are mandatory.
The basis for healthy living and a long service life for your windows.
Modern windows seal extremely well, which brings greater living comfort and lower heat loss. However, to maintain a healthy indoor climate and prevent excessive humidity or mould growth, proper ventilation is essential. On this page you will find practical recommendations on how to ventilate effectively throughout the year and extend the service life of your windows and the entire building.
Why is proper ventilation important?
Regular air exchange affects living quality more than many people realise. It helps prevent excessive humidity, mould growth, window damage, and at the same time creates a healthier environment for everyday living.
Healthier air
Regular ventilation ensures a healthier indoor climate, reduces CO₂ concentration, and improves living comfort.
No excessive humidity
Keep relative humidity at approximately 40 to 60% to limit condensation and mould growth.
Longer window service life
Proper ventilation protects windows and building structures from excessive moisture and helps extend their service life.
The relationship between indoor air quality and winter construction damage to wood windows
The relationship between air humidity, carbon dioxide content, the energy required for ventilation, and damage caused by insufficient ventilation is often not clear. We would like to explain this issue below:
Amount of water vapour during the construction phase
When drying new buildings, a large amount of water vapour escapes from interior plasters and screeds. The relationship between the amount of water produced and the period during which water vapour diffuses through walls and windows without ventilation is explained using an example:
In a room of 30 m² (height 2.5 m), a screed (4 cm thick) and interior plasters (1.5 cm thick) release a total of approx. 500 l of water during drying over approx. 4 weeks. This corresponds to a water vapour volume of approx. 620,000 l (18 g of water = 22.4 l of water vapour). However, with finished window frames of a standard size of 1.25 × 1.25 m, only 1 g of water, i.e. approx. 1.25 l of water vapour per hour, can diffuse when the windows are closed. It is assumed that window frames account for 4% of the wall area and, of course, only 4% of the generated amount of water (approx. 20 l) diffuses through the window frames, which results in a period of more than 2 years. This shows that without sufficient ventilation, the water vapour generated during the drying of screeds and interior plasters cannot escape from a new building within the required time.
The consequences of incorrect room ventilation are so-called winter construction damage. Water vapour penetrates the wood through weak points (e.g. the glazing rebate area or poorly varnished surfaces in the masonry), condenses, and increases the wood moisture content to more than 30%. This results in windows being difficult to open and leads to damage in glued joints, or increases the risk of attack by wood-decaying fungi. In extreme cases, bubbles form in the coating on the outside of the window, which may be filled with water.
During plastering and the final drying phase, this damage can be prevented with sufficient ventilation (e.g. a tilted window). For further details, see “Window ventilation”.
Amount of water vapour in occupied rooms
Water vapour is a non-toxic, colourless and odourless gas that is continuously produced in large quantities; for example, a four-person household generates an average of 8 to 15 kg per day, which corresponds to a water vapour volume of approx. 10,000 to 19,000 l.
Relative humidity of approx. 40 to 70% is considered normal.
Dry air promotes electrostatic charging and dries out mucous membranes.
With very dry air (below approx. 40%), certain bacteria and viruses multiply, causing bronchial diseases.
With prolonged relative humidity above 60 to 65%, water vapour condenses on smooth areas of external walls, creating a breeding ground for mould.
Preventing water vapour condensation can be achieved by:
perfect external insulation of house walls, if this is not possible
internal insulation of areas with an increased risk of condensation, such as corners, recesses, reveals
active window ventilation so that room humidity does not rise above 50–55% (purchasing a hygrometer to check the actual humidity level is necessary!)
Carbon dioxide CO2
Carbon dioxide is continuously produced by breathing. A high concentration of carbon dioxide in living spaces causes fatigue and reduced concentration. In Europe, a limit value is recognised (the Pettenkofer limit), which is 0.1% CO₂ of the air in the room. The amount of CO₂ produced per person is 10 to 75 l per hour depending on activity. In a four-person household, 2,000 to 3,000 m³ of fresh air per day is therefore required to keep the CO₂ concentration below the critical value. This means that in a 75 m² apartment, air exchange is required every 1.5 to 2 hours; in a family house with 140 m², about every 3 hours.
Window ventilation
The aim of ventilation is to achieve maximum indoor air quality with minimal energy consumption. For active window ventilation, the following points must be taken into account:
The time required for ventilation to completely replace the air in a room during shock ventilation (window fully open) depends on the outdoor temperature (in winter 4 to 6 minutes, in spring and autumn 10 to 20 minutes, and in summer 25 to 30 minutes).
Even a light wind (approx. 5 km/h) can double the air exchange. The strongest driving force for ventilation is thermal buoyancy. The greater the temperature difference between indoors and outdoors, the stronger the tendency of warm air to escape through open windows. Therefore, the time for a complete air exchange in winter is significantly shorter (approx. 5 minutes) than during transitional periods (approx. 15 minutes).
Optimal results were achieved only with controlled ventilation with heat recovery.
The following table shows air exchange rates, i.e. how often per hour a complete air exchange is achieved, for different ventilation methods. An air exchange rate of 1 means a complete air exchange in 1 hour; at a value of 0.5, the air is completely replaced in 2 hours.
Spôsob vetrania
Hodnota výmeny vzduchu za hodinu
Okná a dvere uzavreté tesneniami
0,1 – 0,3
Regulované vetranie
0,2 – 0,8
Sklopené okno
bez priečneho vetrania
s priečnym vetraním
0,8 – 2,5
2,0 – 4,0
Okno otvorené (nárazové vetranie)
bez priečneho vetrania
s priečnym vetraním
9,0 – 15,0
viac ako 20,0
Netesné domy
do 2,0
Summary
When drying screeds and interior plasters, the resulting vapour must be removed through sufficient ventilation to prevent damage during the construction phase.
Sufficient ventilation is required so that, during the use of apartments or family houses, a pleasant indoor climate and healthy, high-quality air are achieved in living spaces. Only then can mould growth and moisture-related damage be prevented.
Finally, a few valuable practical tips
Ventilate only in a spatially sensible way; with cross-ventilation through multiple rooms, a maximum of 3 minutes is sufficient for a complete air exchange.
Ventilate actively only when rooms are in use; in unoccupied rooms, ventilation through joints alone is often sufficient.
The very common method of ventilating with tilted windows often leads to an increased air exchange rate because the amount of airflow is underestimated.
Ventilation in the tilted position only makes sense outside the heating season.
In mid-winter, a window should not be left tilted for longer than 7–20 minutes per hour.
Recommended shock ventilation through a fully open window in winter is energy-efficient only if it is carried out very disciplinedly and for a short time (4 to 6 minutes).
Good results can be achieved using a controlled ventilation slot (metered ventilation). One element per room is sufficient.
With all methods of active ventilation, the time the window is open must be based on the outdoor climate. The colder it is outside, the shorter the ventilation time due to stronger thermal buoyancy.
Do you have questions about windows, or are you planning a new build or renovation?
The right choice of windows, their professional installation, and correct use determine living comfort for many years. We will be happy to advise you on selecting the right solution and on technical questions regarding windows, doors, or shading.